Calculation verification
Every result on this page can be checked by hand. For each calculator: the inputs, the formula, a worked example with real numbers, the units, the standard it comes from, and what it does not cover. Worked examples checked against the calculator output on 17 Nov 2026.
Pipe weight and support loadPipe data B36.10M; spans B31.1 Table 121.5; beam formulas
Input parameters
| Parameter | Symbol | Unit | Source |
|---|---|---|---|
| NPS and schedule | D, t | mm | ASME B36.10M / B36.19M |
| Material density, modulus | ρ, E | kg/m³, MPa | 7850 / 203 400 for carbon steel |
| Contents density | ρc | kg/m³ | Process data (water 1000) |
| Insulation thickness and density | ti, ρi | mm, kg/m³ | Insulation specification |
| Cladding thickness and density | tc, ρcl | mm, kg/m³ | Aluminium 0.7 mm, 2700 kg/m³ typical |
| Span | L | m | Support layout (B31.1 table as default) |
| Valve or other load at mid-span | P | kg | Valve datasheet |
| Dummy leg size, length, friction, allowable | NPS, L_d, μ, S | –, mm, –, MPa | Support standard; B31.3 Table A-1 |
Formula used
d = D − 2t; A = π/4 (D² − d²); I = π/64 (D⁴ − d⁴); Z = 2I / D Pipe w_p = ρ · A; contents w_c = ρc · π/4 · d² Insulation w_i = ρi · π/4 · ((D + 2ti)² − D²); cladding w_k = ρcl · π · (D + 2ti) · tc Operating w = w_p + w_c + w_i + w_k; hydrotest w_T = w_p + water Support load: interior of a continuous run R = w · g · L; single span or end R = w · g · L / 2 (+ P/2 for a mid-span valve) Sag, simply supported: δ = 5 w L⁴ / (384 E I); ends fixed: δ = w L⁴ / (384 E I) Bending stress σ = M / Z with M = w L² / 10 (continuous) or w L² / 8 (single span) Dummy leg: σ = P / A_d + μ · P · L_d / Z_d ≤ S
Worked example
NPS 6 STD carbon steel, full of water, 50 mm mineral wool (128 kg/m³) with 0.7 mm aluminium cladding, interior support, span 5.2 m (B31.1 water). Dummy leg NPS 4 STD, 500 mm long, μ = 0.3, S = 137.9 MPa.
- D = 168.3 mm, t = 7.11 mm, d = 154.1 mm; A = 3601 mm²; I = 1.171 × 10⁷ mm⁴; Z = 139 200 mm³
- Pipe 7850 × 3601 × 10⁻⁶ = 28.27 kg/m; water 1000 × 18 639 × 10⁻⁶ = 18.64 kg/m
- Insulation 128 × π/4 × (268.3² − 168.3²) × 10⁻⁶ = 4.39 kg/m; cladding 2700 × π × 268.3 × 0.7 × 10⁻⁶ = 1.59 kg/m
- Operating w = 52.89 kg/m (35.5 lb/ft); hydrotest w_T = 28.27 + 18.64 = 46.91 kg/m
- R = 52.89 × 9.807 × 5.2 = 2697 N = 2.70 kN (275 kg); hydrotest 2.39 kN (244 kg)
- δ (simply supported) = 5 × 0.519 × 5200⁴ / (384 × 203 400 × 1.171 × 10⁷) = 2.1 mm
- σ = 0.519 × 5200² / 10 / 139 200 = 10.1 MPa
- Dummy leg NPS 4 STD: A = 2048 mm², Z = 52 680 mm³; σ = 2697 / 2048 + 0.3 × 2697 × 500 / 52 680 = 1.3 + 7.7 = 9.0 MPa (7% of S)
Result: 52.89 kg/m operating; 2.70 kN per support; sag 2.1 mm; dummy leg at 7% of S.
Units
- kg/m and lb/ft (× 0.672)
- N, kN and kg (÷ 9.807)
- mm, MPa
Standard or engineering basis
- Pipe dimensions: ASME B36.10M / B36.19M
- Default spans: ASME B31.1 Table 121.5 (about 2.5 mm sag, 16 MPa)
- Beam theory for sag and bending; allowable stress from ASME B31.3 Table A-1
Assumptions and limitations
- Weight only: wind, seismic, friction loads on supports and thermal or pressure effects are not included.
- Support load assumes equal spans; unequal spans, risers and branches change the share each support carries.
- Flanges, fittings and insulation on fittings add weight; add them as point loads or a margin (often 10–15%).
- The dummy leg check covers the leg only. Local stress in the elbow at the dummy leg weld needs a stress engineer's check on hot or large lines.
- Hydrotest weight assumes insulation is fitted after the test.