A buried pipeline is protected from corrosion by cathodic protection: a small current that makes the steel the protected side of a cell. If the pipeline touches earthed plant piping, that current leaks away and protection fails.

What the kit is

An insulating flange kit turns an ordinary flange joint into an electrical break. It has:

  • An insulating gasket, often glass-reinforced epoxy with a sealing element.
  • An insulating sleeve for every bolt, so the bolt does not touch the flange holes.
  • Insulating washers under the nuts, then steel washers on top.

Kits come as full-face, raised-face ring and ring-joint types to suit the flange face.

Where they are used

  • Where a buried, cathodically protected line comes above ground and joins plant piping.
  • Between the pipeline and equipment or structures that are earthed.
  • Between dissimilar metals, to stop galvanic corrosion.

Flange kit or monolithic joint?

A monolithic insulating joint is a factory-made, welded-in piece that is tested before delivery. It suits buried and high-pressure duty. Flange kits suit above-ground points where they can be inspected and tested.

Installation

  • Put the joint above ground, close to where the line emerges, before the first earthed support.
  • Make sure nothing bridges the joint: no metal support, instrument tubing or jumper touching both sides.
  • Use bolt sleeves long enough to cover both flanges and the washers.
  • Tighten to the kit maker's torque; insulating gaskets take less load than metal ones.
  • Test it after installation and before backfill or painting, with the method in the project specification.
  • Where lightning or fault currents can reach it, a spark gap or surge arrester is fitted across it, never a plain jumper.

Common questions

Why does a cathodically protected pipeline need an insulating joint?

Without it the protection current flows into the earthed plant piping and earth grid, and the pipeline is left unprotected.

Do the bolts need to be longer?

Often slightly, because of the insulating and steel washers. Check the bolt length with the kit in place.

Can I put a jumper across it for static?

No. That shorts the joint. Use a spark gap or surge arrester if the electrical engineer requires protection.