Pipe Ref
Units

Piping guides

Short, plain answers to the questions piping engineers and designers search for, each linked to the tool that does the work.

Gate valve vs globe valve: what is the difference?Both are linear valves with a handwheel and a rising stem, and on a drawing they look almost the same. Inside they work very differently, and that decides where each one belongs.What is a trunnion support?A trunnion is a short piece of pipe welded to a process line so that the line can sit on a support. It turns an awkward support point, like an elbow or a pipe high above the steel, into a simple rest.Pipe schedule explained: Sch 40 vs Sch 80A pipe schedule is a wall thickness series. For a given pipe size, every schedule has the same outside diameter; only the wall, and so the bore and the weight, changes.Weld neck vs slip-on flangeBoth are ASME B16.5 flanges that bolt up the same way. The difference is how they join the pipe, and that changes their strength, inspection and cost.RF vs RTJ flange facesThe face of a flange decides which gasket it takes. Raised face is the everyday choice; ring type joint is for high pressure and temperature.How to calculate hydrotest pressure (ASME B31.3)A hydrotest proves the piping is strong and tight before it goes into service. B31.3 sets the minimum test pressure with one short formula, but a few checks decide whether you can actually use it.Sizing an expansion loop with the guided cantilever methodA hot pipe grows. If nothing gives, that growth pushes on anchors and nozzles. A loop or a bend gives the pipe somewhere to flex. The guided cantilever method sizes it in a minute.Long radius vs short radius elbowLong radius elbows are the default in process piping. Short radius elbows save space, at a cost in pressure drop and stress.Pipe shoe, guide, line stop and anchor: what each one doesEvery pipe support is defined by which directions it stops the pipe moving. Learn the four basic ones and most support drawings start to make sense.Spectacle blind, paddle blind and spacerValves can leak. When a line has to be positively isolated, for maintenance or between services, a solid plate goes between two flanges. ASME B16.48 covers these line blanks.P&ID valve symbols: how to read themAlmost every valve on a P&ID starts from the same shape: two triangles meeting point to point. What is added in the middle, on top or filled in tells you which valve it is.How to calculate pipe cut length from an isometricAn isometric gives centre-to-centre or centre-to-face dimensions. The pipe you cut is shorter: you take off what each fitting adds, and the gap for each weld.