Pipe schedule explained: Sch 40 vs Sch 80

A pipe schedule is a wall thickness series. For a given pipe size, every schedule has the same outside diameter; only the wall, and so the bore and the weight, changes.

Same outside, different inside

ASME B36.10M fixes the outside diameter of each pipe size, so fittings and flanges fit every schedule of that size. A higher schedule number means a thicker wall. The extra metal goes inwards, so the bore gets smaller.

SizeODSch 40 wallSch 80 wallSch 40 weightSch 80 weight
NPS 260.3 mm3.91 mm5.54 mm5.44 kg/m7.48 kg/m
NPS 6168.3 mm7.11 mm10.97 mm28.3 kg/m42.6 kg/m

So Sch 80 holds more pressure and has more corrosion margin, but it is heavier, costs more, and has a smaller bore.

STD, XS and XXS

These are older weight names that are still used. STD is the same as Sch 40 up to NPS 10, and XS is the same as Sch 80 up to NPS 8. Above those sizes they are different, so never swap them on large lines without checking the table.

Stainless steel: 40S and 80S

Stainless pipe follows ASME B36.19M, with schedules ending in S (5S, 10S, 40S, 80S). For most sizes 40S equals Sch 40, but not for all, and the thin 5S and 10S walls are common in stainless because the material does not corrode away.

How the schedule is chosen

  1. Work out the pressure design thickness, for B31.3 with Eq. (3a): t = PD / 2(SEW + PY).
  2. Add the corrosion allowance (and thread depth for threaded pipe).
  3. Allow for the mill under-tolerance, usually 12.5% for seamless pipe.
  4. Pick the lightest schedule at least that thick, then check that branches, bends and supports still work with it.

In practice the piping class already lists the schedule for each size; the calculation is how that table was made.

Common questions

Is Sch 40 the same as STD?

Up to NPS 10, yes. From NPS 12 the STD wall stays at 9.53 mm while Sch 40 gets thicker, so they differ.

Does a higher schedule change the outside diameter?

No. The OD is fixed for each pipe size; a higher schedule only makes the wall thicker and the bore smaller.

Why is my 6 inch pipe not 6 inches across?

NPS is a size name. Up to NPS 12 the actual OD is larger than the name (NPS 6 is 168.3 mm, 6.625 in). From NPS 14 the OD equals the size in inches.

More guides

General engineering guidance for learning and early design. Your project specifications and the governing code edition always take precedence.